Home repair tips you can share
396 facts across 99 repairs · Updated 2026-11-20
Every tip below is lifted from one of our guides, and every guide is built from official sources — manufacturer manuals, the Florida Building Code, and Orange County / City of Orlando building-division pages. Tap Share to send one to a neighbour, or open the full guide. For a plan tailored to your exact repair, try the free DIYrr app.
Plumbing & water
20 repairs
Bathroom Faucet Replacement
-
Measure the sink holes BEFORE buying (Moen): one hole = a single-hole faucet; three holes 4" apart (center of hot handle to center of cold) = any centerset; 8-16" = widespread.
-
Faucet: 'Apply plumbers putty or other sealant to the underside of the escutcheon according to the manufacturer's instructions' (Kohler).
-
Pop-up drain: ring of plumbers putty or other sealant under the flange; hand-tighten the flange from the top, snug the nut from below — 'Be careful not to rotate the drain when tightening the nut' — and keep the lift rod hole 'facing the back of the fixture'; wipe off excess putty (Kohler).
-
Stopper: adjust so it 'lifts about 3/8" (1 cm) when opened' by turning the threaded stopper rod. (Kohler)
Bathroom Vanity Replacement
-
Measure before you shop, in this order: the width you have wall to wall (or wall to toilet), then where the drain and the two supply stubs come out of the wall, measured from the side wall and up from the floor.
-
Common sizes: Ferguson Home's vanity guide puts single-sink vanities at 24 to 61 inches wide and double-sink vanities at 48 to 80 inches, with the top overhanging the cabinet by 'an inch or more'.
-
Code spacing that catches small bathrooms (Florida Building Code, Plumbing 405.3.1): a lavatory 'shall not be set closer than 15 inches from its center to any side wall, partition, vanity or other obstruction', adjacent fixtures no closer than '30 inches center to center', and 'not less than a 21-inch clearance in front' of the sink or toilet.
-
Removal: shut the two stops under the sink (if they won't close or they weep, close the house valve and plan to replace them), disconnect the supply lines and the slip nuts on the P-trap with a bucket under it, cut the caulk line between the top and the wall and the base and the floor with a utility knife, then back out the screws through the cabinet's rear rail into the studs.
Cast Iron Drain Pipe & Repipe Repair
-
Replacing corroded drain pipe is permit work, and the code says so in the same sentence as the exemption.
-
The tip that saves five figures: in Florida you may NOT line a pipe that has already failed.
-
The camera survey is code, not an upsell.
-
Do not let sewer-and-drain grade PVC go under your slab.
Faucet / Shower Cartridge (Moen 1222/1225 · Delta 1300/1400) Repair
-
Shut water off AND open the handle to bleed pressure; cover/plug the drain BEFORE pulling the retainer clip — that clip is the part most often lost down the drain on both Moen and Delta valves.
Full faucet / shower cartridge (moen 1222/1225 · delta 1300/1400) guide →
-
Moen: pull the retainer clip first with needle-nose, then loosen with the white twist cap shipped with the new cartridge.
Full faucet / shower cartridge (moen 1222/1225 · delta 1300/1400) guide →
-
Buy the Moen cartridge by PART NUMBER, not by faucet looks — the three are not interchangeable: 1222 = PosiTemp tub/shower; one-handle kitchen/lav faucets produced BEFORE 2009 take the 1225, AFTER 2009 the 1255 Duralast (Moen: 'date varies based on style and model', so confirm the model before buying).
Full faucet / shower cartridge (moen 1222/1225 · delta 1300/1400) guide →
-
Lubricate O-rings with SILICONE grease only (Moen 99915); Moen bans petroleum 'plumber's/stem grease' and Vaseline — they swell the rubber and make the cartridge fail.
Full faucet / shower cartridge (moen 1222/1225 · delta 1300/1400) guide →
Garbage Disposal Repair
-
Connecting a dishwasher: remove the dishwasher inlet plug FIRST — older/Badger 3-bolt units tap it out with a screwdriver + hammer; newer EZ Connect units insert the wrenchette into the plug and turn it 90° counter-clockwise.
-
Replacement swap: if the existing sink-flange mount is sound, reuse it and just hang the new unit — but the disposer must match that mount system (3-bolt vs quick-lock); they don't interchange.
-
3-bolt mount: 1/2" rope of plumber's putty under the sink flange, then tighten the 3 mounting screws ALTERNATELY a few turns each so it seats evenly (uneven = flange leak).
-
Jams: power off at switch AND breaker; never hands in chamber; insert the 1/4" hex wrenchette in the bottom-center socket and work back and forth.
Hose Bib / Outdoor Spigot Repair
-
FL code (FBC-R 2023 P2902.4.3): every sillcock/hose bibb needs an ASSE 1011/1019/1052 vacuum breaker or hose-connection backflow preventer — buy an anti-siphon bib, or permanently attach a screw-on hose-connection VB (tighten its set/break-off screw so it can't be removed).
-
Orlando spec: frost-free sillcocks are unnecessary — 'mild climate' anti-siphon wall faucets (e.g. Woodford Model 24, NIDEL 34HF vacuum breaker, ASSE 1011) are the correct class.
-
Anti-siphon bibs must NOT stay pressurized >12 consecutive hours — hose-end irrigation/drip timers and closed Y-shutoffs (common in Orlando) are explicitly 'not designed for constant pressure' and wreck the VB seals.
-
A new/replacement VB may spit until it is seated — hose on, nozzle CLOSED, faucet full blast until the hose fills. On a frost-proof hydrant a steady gentle drain for ~15-20 sec after shutoff is normal, not a leak.
Kitchen Faucet Replacement
-
Check the connection BEFORE buying: Moen faucets 'typically utilize either flexible supplies with 3/8" compression fittings or 1/2" IPS connections' — if the existing supply lines or shut-off valves don't fit, get the adapter for that model (Moen's Replacement Part Locator gives the connection type).
-
Shut off both supply valves under the sink first (Moen: 'The water supply shut off valves must be turned off'); Delta's tool list adds a bucket, flashlight and safety glasses for the work under the sink.
-
Supply lines: blue = cold, red = hot. Hand-tighten, then 'one wrench turn past finger-tight should be tight enough' (Delta). (~3 in)
-
Pull-down hose: slide the hose weight onto the hose before connecting (Delta). Quick connects lock with a press or an audible click — then 'gently tug on the quick connect to verify it is secure' (Moen).
Kitchen Sink Replacement
-
Three mounts, and the countertop decides which you can have.
-
Measure the old sink before you shop.
-
Removal: close both supply stops (if they won't shut, close the house valve), disconnect the faucet supplies, the trap's slip nuts with a bucket under them, the disposal (hang its weight, then twist it off its mount) and the dishwasher drain hose.
-
Drop-in install (Kohler self-rimming): 'If possible, assemble the faucet and drain assembly to the sink before installing the sink'.
Main Water Shut-Off & Leak Check Repair
-
Know your two shut-offs before you need them.
-
Past the meter it's yours: Orange County Utilities — 'All pipe maintenance after the water meter is the sole responsibility of the property owner'.
-
The 10-minute leak test (EPA WaterSense): read the water meter, 'avoid all water use for two hours, then read it again.
-
Toilets are the usual culprit.
Septic Tank & Drainfield Repair
-
Florida septic rules moved to DEP and the old DOH chapter 64E-6 is repealed, but in Orange County you still apply at the county health department.
-
You may work on your own system, but you may never skip the permit — and a 2026 law changed WHEN you must have it.
-
Pumping the tank is not a permitted repair. A drainfield "rejuvenation" service is.
-
Selling and remodeling: the rules are homeowner-friendly, but the paragraph letters MOVED in 2026. Ch.
Shower Door Install & Re-Seal Repair
-
Measure like the instruction sheets do: wall to wall 'at the top, middle and bottom' and 'use the smallest measurement as the finished opening' (DreamLine).
-
Which way and which side: 'the door MUST ALWAYS open outward' (Basco) and 'Install the pivot jamb of the door on the side opposite the showerhead' (Sterling), the same rule Basco gives 'for maximum water proofing'.
-
Removing the old door: slice the silicone along both wall jambs and the bottom track with a utility knife, back out the jamb screws, lift the panels out of the header, then work the jambs and track free; scrape the old silicone off the tile and curb and clean until the surfaces are 'clean, dry ...
-
Track first.
Shower Head & Handheld Replacement
-
Taking the old head off: 'Unscrew the showerhead from the shower arm. Rotate counterclockwise. (Delta)
-
Tape or no tape depends on what seals the joint.
-
Handheld kits are hand-tight joints. Moen's combination head: 'Tighten diverter to shower arm with wrench. Hand tighten fixed showerhead to front of diverter. (Moen)
-
Replacing the arm itself: 'Unscrew the shower arm by hand and remove the flange. A pipe wrench or pliers might be necessary' (Moen), then 'Apply sealant tape to the threads of each end of the shower arm.
Sink Drain / P-Trap Repair
-
Slip joints seal with the washer, not with tape: Oatey's order is "The nut goes on first, followed by the washer, with the tapered side of the washer facing the fitting" — reversed washers are the classic trap drip.
-
Trap geometry is code, not preference (FBC-Plumbing 1002): liquid seal "not less than 2 inches...
-
Slope and size: horizontal drainage pipe 2-1/2 in or less slopes 1/4 in per ft (FBC-P Table 704.1).
-
A sink that gurgles or smells of sewer after a new trap is a VENT problem, not a trap problem: FBC-P 909.1 caps the developed length from the trap weir to the vent fitting per Table 909.1 — 5 ft on a 1-1/4 in trap, 6 ft on 1-1/2 in, 8 ft on 2 in (at 1/4 in per ft).
Slow Tub / Shower Drain Repair
-
Start at the stopper, not the chemicals. Delta: a lift & turn tub stopper 'unscrews counterclockwise while in the "full up" position'. With a toe tap, 'the cap may come off the plunger before the whole stopper does.
-
If it spins and won't come out: Delta — 'the threads are stripped, and you will need to exert upward pressure while unscrewing. If that fails, you will have to unscrew the bath waste flange from the drain pipe.
-
Shower with a grate: Delta says to take the cover off with a screwdriver and clean it thoroughly; 'it tends to get full of hair and soap scum as well, and could be contributing to your drainage problem.'
-
Fish, don't push: bend a hanger into a hook, 'stick the hook end into the shower drain hole as far as it will go, rotating the hanger as you push it down. Then jiggle the hanger to lift, or fish out, any hair and gunk. (Delta)
Toilet Repair
-
BEFORE buying, measure the rough-in (finished wall to the center of the closet bolts) and match it to the new toilet's own spec sheet — Kohler's install guide says only to 'conform to the roughing-in dimensions' and each model lists its own (e.g.
-
Press the wax seal onto the TOILET outlet (not the flange), lower over the flange, set with full body weight — then DO NOT lift or rock the bowl; a broken seal means a NEW wax ring, never re-seat.
-
New 5/16" T-bolts AND tank bolts: tighten to SNUG only — Kohler: overtightening tank bolts can break or chip the vitreous china; verify the tank sits level front-back and left-right, and cut floor bolts extending >=1/4" above the nut.
-
Flange height (Fluidmaster 7530 waxless seal kit): flange even with floor or up to 1/4" below = spacer (foam side DOWN) + one seal; MORE than 1/4" below = spacer + TWO seals (2nd sold separately); depth over 1/2" below = flange extender required; flange ABOVE the floor = one seal, no spacer.
Toilet Seat & Bidet Seat Repair
-
Round or elongated: measure from the center of the seat bolts to the front edge of the bowl.
-
Getting the old seat off: 'Locate the nuts under the toilet tank and grip them firmly with pliers in one hand' while a screwdriver turns the bolt from above (Bemis); corroded hardware gets 'rust penetrant ...
-
Installing: snap-off hardware is the one that stays tight. Bemis STA-TITE: 'Insert bolts', 'Push bushing onto bolt', 'Place seat on bowl', 'Attach nuts.
-
Will a bidet seat fit?
Tub/Shower Caulking Repair
-
Remove 100% of the old caulk — nothing bonds over old sealant or residue.
-
On a flexing tub (GE names fiberglass) fill it with water before caulking and keep it full until the bead skins: "Tubs will naturally sink and flex from the weight of the water, putting stress on the sealant joint.".
-
Spec 100% silicone for tub/shower joints (permanently flexible; GE claims mold resistance up to 10 years).
-
Water-ready times are conditional, not universal. GE Advanced Silicone 2: "Exposure to water possible in as little as 30 minutes with bead size max 3/16\", temperature min 65℉ and humidity min 50%.
Water Heater Repair
-
T&P relief valve: NO valve of any type between it and the tank (Rheem).
-
A relief valve that opens every heating cycle = thermal expansion on a CLOSED system (check valve in the cold line: backflow preventer, PRV, meter or softener) Rheem: 'Replacing the relief valve will not correct the problem!' Rheem's suggested fix is an expansion tank on the COLD line.
-
Drain pan (FBC-R P2801.6.1/.6.2): at least 1-1/2" deep, indirect drain pipe at least 3/4", full size to an indirect waste receptor OR out through the exterior ending 6-24" above adjacent ground.
-
Electric branch circuit (Rheem guide, NEC Table 310-16 at 75°C): 4,500W/240V = 25A + 10 AWG copper; 5,500W = 30A + 10 AWG copper. Match the voltage and wattage on the rating plate before buying or wiring.
Water Heater No Hot Water
-
No hot water on an electric unit: check the dedicated 240V breaker FIRST and reset it once — a breaker that trips again is a fault, so stop there. (A.O. Smith)
-
Reset the high-limit safety the right way, ONCE: power off, pull the access panel covering the UPPER thermostat, and 'press the reset button firmly until you hear it click.' A click means the water overheated and tripped the cutoff 'often due to a grounded heating element or a faulty lower thermostat'. (A.O. Smith)
-
GAS unit, no hot water: the pilot is the usual suspect, and the thermocouple is why it matters. (A.O. Smith)
-
Pin the culprit before buying parts (A.O. Smith Technical Bulletin 36, 'Not Enough Hot Water - Electric'): set both thermostat dials to 130°F, run about 15 gallons and shut the water off the heater 'should complete heating 15 gallons in approximately 45 minutes,' and the water then 'should fall between 120°F to 140°F'. (A.O. Smith Bulletin 36)
Water Softener / Filter Repair
-
Softener using no salt / water suddenly hard = suspect a salt bridge: push a broom handle down into the salt; hitting a hard crust that isn't the tank wall/bottom confirms it. (GE)
-
Salt rule (GE): refill when the brine tank is 1/4 to 1/2 full and never let it run empty; in humid Florida, fill with LESS salt more often - overfilling promotes salt bridging.
-
Set hardness for Orlando correctly: OUC water averages 129 ppm = 7 grains per gallon (official OUC figure).
-
Always put the unit in bypass before any service: single-valve bypass = PUSH IN for bypass, PULL OUT for service (GE). Plumbed 3-valve bypass layouts vary: follow the unit's manual.
Electrical & smart home
11 repairs
Breaker Keeps Tripping Repair
-
A breaker that keeps tripping is doing its job: it protects the wire in the wall, not the appliance, so a bigger breaker is never the fix. This is the mistake that burns houses down, and the code puts hard numbers on it.
-
Before you guess, read the code the breaker already stored — a modern AFCI or dual-function breaker RECORDS why it tripped.
-
The two arc codes split the job between you and an electrician, and they mean opposite things.
-
Square D can also be asked, on demand, to NAME the fault — Time Saver Diagnostics.
Ceiling Fan Repair
-
The box MUST be fan-rated (Hunter: supports 70 lb; typically marked 'Approved for Ceiling Fans' or 'Rated for 70lbs').
-
Clearances (Hunter): blade bottoms >=7 ft above the floor; blade tips >=30" from the nearest wall or obstruction. Pick the downrod length with both in mind.
-
Sloped ceiling: needs a longer downrod (sold separately), and low-profile/hugger fans cannot be mounted on an angled ceiling at all.
-
Downrod assembly: hand-tighten the downrod at least 4-5 turns, then tighten the setscrew with pliers (not by hand); leave ~8" of wire above the rod and strip 3/8". Lift the fan only by the housing or downrod.
Doorbell & Video Doorbell Repair
-
A video doorbell needs TWO transformer numbers and VA is the one people miss.
-
Under-powering damages hardware rather than just under-performing, and each brand has a tell. Ring: the wrong rating can "Damage your devices" and "Stop your in-home chime from working properly.".
-
The wire is a spec too. Ring: "Use 16- to 20-gauge wire for your Ring doorbell. Wires that are too thin or too thick might not deliver enough power to your Ring device.".
-
The in-home chime kit is mandatory and ships in the box.
Flickering Lights / Low Water Pressure
-
FLICKER TRIAGE ORDER: one bulb/fixture -> tighten bulb, then swap non-dimmable LED for a bulb on Lutron's LED compatibility (LED Finder) tool, then adjust dimmer low-end trim (flicker only at low dim = bulb can't dim as low as dimmer); Lutron: lights that flash or strobe — confirm 2 Caséta dimmers are not controlling the same lights.
-
Flicker in several rooms, or that stays after the bulb and dimmer steps above, is not a bulb/dimmer problem. HARD STOP: no DIY panel or service-side work — have a licensed electrician find the cause.
-
FL older-home flag: Federal Pacific (Stab-Lok) or Zinsco panel = panels have a reputation for problems; InterNACHI says further evaluation by a qualified electrician is recommended.
-
ONE-FIXTURE low pressure (Moen order): check the supply lines/stop valves give the faucet full pressure -> remove the aerator and rinse out debris -> pull-out/pull-down faucets: remove the hose from the wand and rinse the screen between them; if still low, replace the wand -> last resort: replace the cartridge and flush/clean the valve body.
Generator Hookup & Transfer Switch
-
The dividing line is the panel: cords from a portable generator to appliances need no permit, but ANY tie into house wiring — transfer switch, interlock kit, or inlet box — is an electrical alteration.
-
Never plug a generator into a wall outlet. (CPSC)
-
Neutral bonding is the hookup error that hides, and it runs OPPOSITE ways for the two generator types.
-
Standby siting is four clearances that must ALL hold at once — one openable window kills a spot that clears the wall: 18 in (457 mm) minimum at the REAR (a Southwest Research Institute listed-enclosure allowance against NFPA 37 Sec. (Generac)
GFCI Outlet Repair
-
LINE vs LOAD is the make-or-break step: LINE = cable from the panel (one cable in box = LINE); LOAD terminals sit under a factory yellow sticker — leave the sticker on if not feeding downstream outlets.
-
LINE wires landed on LOAD = the GFCI will not reset and gives no power; Leviton: the unit ships from the factory tripped and cannot be reset until wired correctly and powered — the #1 DIY callback.
-
Status LED (Leviton Self-Test): GREEN = passed self-test, protected and powered.
-
One GFCI at the first receptacle protects every receptacle wired to its LOAD terminals — put a 'GFCI PROTECTED OUTLET' sticker on each receptacle that lost power when you tested.
Light Fixture Swap
-
Switch OFF does not mean dead: NCVT-test EVERY conductor in the box before touching (hot, neutral, and switch-leg wires) — Klein NCVT manual: 'Never assume neutral or ground wires are de-energized.
-
Wire nuts per Ideal Wing-Nut instructions: pre-twisting is 'acceptable, but not required'; strip to model spec (451 = 3/8 in solid, 452 = 1/2 in); lead the fixture's STRANDED wire slightly ahead of the solid house wire, insert bundle, twist clockwise until tight; connector must be sized to the wire combo; Cu-to-Cu and dry locations only.
-
Box limits (NEC 314.27): a standard ceiling outlet box supports a max 50 lb luminaire anything heavier (large chandeliers) must be supported independently of the box unless the box is listed/marked for the weight. (NEC 250.148)
-
Location listing (NEC 410.10): covered porch/exterior soffit = DAMP location (fixture must be marked 'Suitable for Damp Locations' or wet); anything exposed to weather or direct spray = WET ('Suitable for Wet Locations'). (wet-rated if subject to shower spray)
Light Switch & Dimmer Repair
-
Count WIRES, not screws, and tag the common BEFORE the old switch leaves the wall — nothing about the wire colours identifies it afterward.
-
A dimmer will not partner with the plain 3-way switch already on your other wall.
-
What a dimmer must NOT control, verbatim from Lutron: "DO NOT use to control receptacles, fluorescent lighting fixtures, non-ballasted or externally ballasted compact fluorescent lamps, motor operated appliances or transformer supplied appliances.".
-
Smart switches usually need a neutral, and whether you have one is decided by the year the house was wired.
New Homeowner First-Week Checks Repair
-
Day one, find the two water shut-offs: the house valve where the main enters and the valve at the meter (OUC: 'a valve at the meter may need to be closed to make repairs on a suspected leak').
-
Alarms: CPSC — 'Smoke alarms should be on every level of the home, outside sleeping areas and inside each bedroom'; CO alarms 'on each level of the home and outside sleeping areas'.
-
Water heater: NFPA — 'set your water heater to 120 degrees Fahrenheit (49 degrees Celsius) or just below the medium setting.' Most sellers leave it hotter; 120°F cuts scald risk and the energy bill.
-
Dryer: CPSC — clear the lint filter 'before or after each use', and lint should come out of the vent pipe 'at least once a year'. (see the dryer vent guide)
Outlet Relocation / EV Charger Circuit Repair
-
Adding a NEMA 14-50, moving an existing outlet, or running any new 240V/EV circuit is NEW wiring, not a like-for-like device swap: Orange County's permit guide answers 'A new electrical outlet or move an outlet?' with 'Yes, you need an electrical permit' — only an appliance that plugs into an EXISTING outlet is exempt. (Orange County Permitting)
-
For hire this is licensed electrical-contractor work — the handyman under-$2,500 exemption never covers electrical. (Florida Statutes 489.103)
-
An EV charger needs its OWN circuit, sized to the charger, not whatever outlet is already in the garage.
Smoke & CO Detectors
-
Chirp decoder -- count the interval first.
-
Smoke and CO alarms run DIFFERENT clocks -- do not assume 10 years for both.
-
Placement, and the distances that fail an install: inside each sleeping room, outside each sleeping area, every level (USFA); wall mounts within 12 in of the ceiling; pitched ceilings 4 in down from the peak.
-
FL smoke-alarm battery law (FS 553.883) is a permission first, a mandate second.
AC, heat & air
7 repairs
AC Not Cooling / Frozen Coil
-
Diagnostic order (Carrier): thermostat FIRST — confirm it is set to COOL and the setpoint hasn't changed — then check the air filter.
-
Frozen coil: switch thermostat COOL->OFF, then set the fan to ON (not Auto) to help thaw; Trane says thawing 'may take a few hours'. (it only clears the outdoor coil)
-
If a new filter and clear vents/drain don't stop the freezing, call a tech (Trane): a refrigerant leak needs a trained professional, and a dirty evaporator coil is a hire-a-pro job rather than a DIY coil-cleaner tutorial.
-
Refrigerant is never DIY: EPA Section 608 requires certification for attaching gauges and adding or removing refrigerant, and only Section 608 certified technicians can buy refrigerant for stationary equipment.
Bathroom Exhaust Fan Repair
-
Size by VOLUME, not floor area: Broan's current method is length x width x CEILING HEIGHT x 0.13, rounded up to the next ten (10 x 8 x 9 ft = 93.6 -> 100 CFM).
-
CFM sets the legal duct size, not what fits the hole. FBC-R Table M1506.2 caps 4" FLEX at 56 ft @50 CFM, 4 ft @80 CFM, and NOT ALLOWED at 100 CFM (4" smooth-wall: 114 / 31 / 10 ft).
-
FBC-R M1501.1 verbatim: 'Air shall not be exhausted into an attic, soffit, ridge vent or crawl space' - the classic Orlando attic-dump defect that grows mold; M1507.2 separately bars recirculating bath air anywhere inside.
-
Central FL humidity: run the fan through the shower and >=20 minutes after.
Furnace / Heat Won't Start
-
Order: thermostat first — mode=HEAT, setpoint above the current room temp, replace thermostat batteries; then the furnace/air-handler power switch (looks like a light switch on or beside the unit; must be ON) and the breaker labeled Furnace/Heat.
-
Heat pumps (the FL default): indoor and outdoor units have SEPARATE breakers — check both. If it cools fine but won't heat, a stuck reversing valve is a pro repair.
-
A steam cloud off the outdoor unit plus 'AUX' on the thermostat is a NORMAL defrost cycle (ice melting; electric strips keep the house warm).
-
Gas furnace totally dead after power checks: the blower-door interlock switch must be engaged (panel fully seated) for the furnace to energize — Goodman's service manual lists a faulty/open interlock as a no-power cause.
HVAC Air Filter Repair
-
Check it monthly, change it on schedule: EPA says manufacturers 'typically recommend replacement every 60 to 90 days, but if filters appear heavily soiled when you replace them, you should consider changing them more frequently', and its own tip is to check every month, 'especially during heavy use months (winter and summer)'.
-
Why it matters: a dirty or clogged filter 'can dramatically reduce air flow, increasing furnace run time, wear on the motor and energy consumption' (DOE HVAC guide). (see the AC not cooling guide)
-
Which rating: EPA recommends 'a filter with at least a Minimum Efficiency Reporting Value (MERV) 13 rating, or as high a rating as your system fan and filter slot can accommodate', and says most furnaces and HVAC systems 'can accommodate a MERV 13 filter without creating equipment problems, provided that the filter is replaced frequently'.
-
The catch: 'Higher MERV filters do tend to restrict airflow'. DOE's guide notes the fixes are more surface area: a deeper pleated filter or 'two furnace filters side by side' in the return.
HVAC Condensate Line Repair
-
Size, slope, and where it may legally end: 3/4-in nominal minimum (FBC-M 307.2.2 the sizing table only steps up past 20 tons, so every house is 3/4 in) and the line may NEVER reduce downstream.
-
Don't crack the drain pan: the pan's 3/4-in NPT female ports take a 3/4-in NPT male PVC or metal fitting HAND-tightened to no more than 37 in-lbs — Goodman expects only 3/8 to 1/2 in of insertion (3-5 turns) at that torque, and wrenching it further splits the pan boss.
-
Trap it the way the MAKER says — 307.2.4 defers entirely: "Condensate drains shall be trapped as required by the equipment or appliance manufacturer.". (307.2.4.1)
-
AC dead in summer = check the float switch FIRST before condemning parts.
Thermostat Replacement
-
Kill the HVAC breaker or the air-handler switch first — Google: "You should always turn off the power before you connect or disconnect any wires"; Honeywell: "turn off the power at the breaker box or switch that controls your heating and cooling.".
-
Photograph the wiring with the TERMINAL LETTERS legible before pulling anything, and label by terminal — Honeywell is explicit: "There is no standard for which color wire controls each function.
-
Confirm it's a 24V system before buying: Nest works with "most 24 V systems, even older systems," but high-voltage thermostats are "usually labeled 110, 115, 120 or 240 VAC" (electric baseboard/radiant), millivolt wall and floor heaters "can't deliver the right amount of power," and non-standard terminal labels (1/2/3 or A/B/C) mean a proprietary system.
-
C wire: Google's required list is broader than most people assume — "Some systems, including heat-only, cool-only, zone-controlled, and heat pump systems, require a C wire" or the Nest Power Connector.
Water Stain On Ceiling Repair
-
SAG BEFORE STAIN — a bulge is a collapse risk, not a stain, and the room needs clearing first.
-
TIMING narrows it faster than colour does — stain colour tells you nothing reliable, so never diagnose from it. Wet during or after rain, dry between storms -> roof.
-
HVAC is the most common Florida cause and the stain lands under the air handler or its drain line.
-
CONFIRM THE SOURCE before opening anything. ROOF — check from the ATTIC, not the roof, while it is actually raining: look above the stain for a wet truss, wet insulation or a daylight pinhole.
Appliances
10 repairs
Dishwasher Install/Swap
-
Drain connection (FBC-P 8th ed §409.4): the waste line must land on a wye branch at the kitchen-sink tailpiece, on the disposer's dishwasher connection, or through an air break to a standpipe, AND 'rise and be securely fastened to the underside of the sink rim or counter top' — strap/zip-tie it, don't drape it.
-
Draining into a garbage disposal: knock the dishwasher-inlet knockout plug INTO the disposer with a hammer + screwdriver and pull it out with needle-nose pliers BEFORE clamping the hose (Whirlpool) — GE: 'DISHWASHER WILL NOT DRAIN IF PLUG IS LEFT IN PLACE,' the #1 first-run 'defect' and an avoidable non-warranty service call.
-
Handling + anchor order: GE says lay the unit on its BACK — 'Do not place the dishwasher on its side' — never kick the wood shipping base, and pull the 4 leveling legs off it with a 15/16" socket before discarding it.
-
Water hookup: 3/8" minimum HOT line — copper with a compression fitting or a dishwasher-rated braided line; Whirlpool: 'Plastic tubing is not recommended,' and the 3/8" compression x 3/4" hose fitting with a 90° elbow is usually NOT in the box.
Dishwasher Not Draining Repair
-
Filter first.
-
New dishwasher that never drained? The disposal's knockout plug.
-
The air gap is the chrome cylinder on the sink; it lets air in so the dishwasher can drain without pulling a vacuum.
-
Drain hose: look for kinks, sagging, and a missing high loop. A proper high loop or a working air gap keeps wastewater from flowing back into the dishwasher (Whirlpool).
Dryer Runs But No Heat
-
FIRST, free: an electric dryer runs on 120V but will not heat without a 208/240V supply, and a double breaker can be partially tripped while looking normal (GE: 'could be partially tripped even if it does not look as though it has tripped').
-
Confirm it's truly no-heat before touching parts: run an EMPTY heated Timed Dry cycle for 5 min, then open the door and feel inside. (Whirlpool product help; GE 16921/16922)
-
Heats but drying takes too long = the vent is likely restricted (Whirlpool). (part W11224254)
-
Thermal cutoff/fuse is a one-shot device that blows FROM a blocked vent. (Whirlpool tech sheet 8535826)
Dryer Vent Repair
-
Max length is set by the DRYER MANUFACTURER, not by a flat 35 ft: FBC-R M1502.4.5.2 — "The size and maximum length of the exhaust duct shall be determined by the dryer manufacturer's installation instructions" (and those instructions go to the inspector).
-
Elbow math when using the code default (Table M1502.4.5.1): deduct 5 ft per 4"-radius mitered 90° and 2'6" per mitered 45°, but only 1'9" for a 6"-radius SMOOTH 90° — swapping mitered for smooth wide-radius elbows (Whirlpool: "45° elbows provide better airflow than 90° elbows") often saves a reroute.
-
Concealed runs must be rigid metal only: 4" nominal diameter, min 0.0157" (28-gauge), smooth interior — GE: "We do not allow anything other than a 4\" round duct," and "Plastic duct work is no longer approved for a safe installation.".
-
Never join duct sections with screws or fasteners that protrude into the airstream — Whirlpool: they "extend into interior of duct and catch lint.". (M1502.4.2)
Fridge / Ice Maker Repair
-
Filter: replace every 6 months (or when the indicator light comes on), then FLUSH 1-4 gal through the dispenser (everydrop Filter A = 1 gal; most other everydrop filters = 4 gal) in 5-sec on/off bursts. (Whirlpool)
-
Temp spec, not just 'cold': LG says the freezer must stay below 19 F, recommends -4 F for ice production, and a warmer setting just makes ice slower, with nothing 'broken'. (LG)
-
Whirlpool: do not feed the ice maker from a softened supply; softener salt can damage ice maker parts and give poor ice. If it can't be avoided, keep the softener working properly and maintained.
-
Supply line: Whirlpool says do not use a piercing-type or 3/16-in saddle valve (reduces flow, clogs easily); use a 1/4-in valve that needs a drilled hole, 1/4-in OD soft copper or PEX tubing, no kinks, and leave a service-loop coil so the fridge can pull out.
Oven Not Heating
-
Order: settings before parts. (all the way left)
-
Power first: ranges need 240/208V. (GE)
-
Bake element: with the range off, breaker off AND unplugged, inspect the lower element for cracks or breaks — damaged = replace (GE sells the part and has a replacement video).
-
Temp sensor (bakes wrong, F10/F30/F31): per a manufacturer service data sheet (brand not stated on it — confirm your model), the oven RTD sensor should read 1091 +/- 5.3 ohms at 75 +/- 2.5F.
Range Hood & Over-The-Range Microwave Repair
-
An over-the-range microwave has two hard numbers: GE and Frigidaire both want '66 in or more from the floor to the top of the microwave' and 'The space between the cabinets must be 30 in wide and free of obstructions', with at least 2 in from the bottom of the unit to the top of the range backguard (GE spec).
-
The outlet is above it, on its own circuit. GE: 'The power supply cord and plug should be brought to a separate 15- to 20-ampere branch circuit single grounded outlet.
-
Hanging it: find the studs ('AT LEAST ONE WALL STUD'), 'Use the mounting plate as the template for the rear wall ... (see the block-wall mounting guide)
-
Venting an OTR microwave: three modes, 'Outside Top Exhaust', 'Outside Back Exhaust' and 'Recirculating', and the blower has to be turned to match. (GE)
Refrigerator Door Seal & Water On The Floor Repair
-
The dollar-bill test (Whirlpool): 'place a dollar bill or piece of paper between the seal and the freezer, pull it out, and retest along the entire door seal.' Paper that slides out with little resistance means a poor seal at that spot; check 'around the entire freezer door perimeter'.
-
Clean before you condemn it: Whirlpool suggests 'a quick wipe-down of the gasket using a damp cloth — no harsh cleaners'.
-
Fridge running all the time?
-
Water on the floor once or twice a day: GE — 'it could be due to a clog in the defrost drain tube.' On some side-by-side models the DIY fix is to flush the drain hole 'with a solution made of 1 tablespoon of baking soda and 2 cups of hot tap water, using a meat/turkey (bulb) baster'.
Refrigerator Not Cooling
-
Check zero-cost causes first, in order: unit powered (no interior light = check plug and outlet), controls not accidentally turned off, not in Showroom/Demo mode (lights on but no cooling; exit sequence varies — see the owner's manual), controls at factory mid setting.
-
Airflow first (Whirlpool): air must flow freely between the freezer and fridge sections. Bulky items blocking the return air vents, items pushed against the back/side walls, or tall stacks obstruct it — leave small gaps.
-
Door seal: confirm the gaskets seal and nothing (packaging, bins) blocks closure.
-
Condenser coils: unplug or kill the breaker FIRST, pop the base grille, vacuum with a soft coil brush; don't bend fins.
Washing Machine Repair
-
Supply hoses: replace damaged hoses when found or every 3-5 years, and keep at least 4 in. between washer and wall so hoses don't kink (State Farm). (Oatey)
-
Leaving town: shut off both washer supply valves if you'll be gone from home an extended period (American Family Insurance).
-
Front-loader slow to drain or showing an OE error: clean the drain pump filter monthly — access panel is at the lower front left (some models right); set a shallow pan and towel by the panel (water runs out), turn the filter counter-clockwise to remove, reinstall clockwise until it stops (LG).
-
Anti-siphon rule (Whirlpool): the drain hose must not extend more than 4.5 in. into the drainpipe, must NOT be sealed with tape (loose but secure, with an air gap), and the top of the drain must be at least 30 in.
Doors & windows
12 repairs
Door Latch & Strike Plate Adjustment Repair
-
Find where it hits before you change anything. Schlage: 'Put some chalk – lipstick also works – on the bolt before locking and unlocking it', then read the smear on the strike.
-
Tighten first, it's free. Loose hinge or strike screws let the door drop and the latch ride low. Schlage: 'worn or loose hinges cause your door to sag', fixed by tighter hinges or 'shims under the hinges'.
-
Door rattles when it's shut: the latch is loose in the strike.
-
Latch misses the hole by a little: file the strike opening toward the latch. This Old House: 'Use a file to enlarge the opening in the direction you need.
Exterior Door & Weatherstripping Repair
-
Diagnose a draft by WHERE it is before buying parts (Therma-Tru).
-
Replacing jamb weatherstrip (Therma-Tru): starting at the TOP of the jamb, pull the old strip out; press the new strip's flat edge into the jamb groove; the new strip will be too long, so scissors-trim it and tuck the loose end into the groove.
-
Door sweep (M-D Building Products economy vinyl sweep): peel-and-stick, cut to length with scissors, seals a gap of up to 1/2" — a larger gap is a sill/door-bottom problem (see the sill adjustment above), not a reason to buy a taller sweep. (Therma-Tru)
-
WATER (not air) intrusion is diagnosed by LOCATION before buying any weatherstrip (Therma-Tru): between sill and subfloor = reseal under the sill; broken seal where sill meets jamb = remove the corner pad, pull the bottom weatherstrip, run a bead of sealant along the whole jamb-to-sill joint, then replace both.
Hurricane Shutters & Window Protection
-
Check whether the parcel is even in a wind-borne debris region before accepting "code requires it.".
-
The wind-mitigation insurance credit is the real payoff, and it is all-or-nothing.
-
Orange County permits shutters and impact units as product work: apply via Fast Track, upload a completed Orange County Product Approval Specification Sheet, and keep the approved installation details on the jobsite — "Failure to do so will result in a failed inspection.".
-
Plywood is a code-recognized fallback with hard numbers, not a sheet leaned against the glass. FBC-R R301.2.1.2 allows wood structural panels not less than 7/16 in.
Interior Door Adjustment Repair
-
Sagging door: before any planing, replace the two TOP-hinge screws nearest the weatherstrip/jamb edge with #10 x 2-1/2" screws driven through the hinge into the wall stud (fastener-maker SPAX's entry-door tip: anchors the frame and prevents sagging).
-
Latch misses strike: smear chalk/lipstick on the latch bolt and close the door to mark the contact point (Schlage's method).
-
Order of operations: tighten/long-screw hinges, then shim or file strike, and only plane as a last resort — Masonite's warranty treats up to 1/4" of warp and seasonal expansion/contraction as 'normal, not a defect,' so wood removal for a seasonal stick is usually the wrong fix.
-
Trim limits are by door TYPE (Masonite support FAQ): MOLDED-PANEL & FLUSH doors allow only 1/8" per edge incl.
Interior Door Replacement
-
Slab or prehung is the first decision. A slab is just the door: you reuse the jamb and hinges, so the old door is your template, and JELD-WEN limits trimming to 'a maximum of 1/4 in ...
-
Measure the old door, not the opening: width, height ('The standard height for interior doors is 6 feet 8 inches'), thickness (interior slabs are 1-3/8 in; Schlage's prep sheet says a lock 'will not fit properly' on a door thinner than 1-3/8 or thicker than 1-3/4), hinge count and spacing, the lock bore and its backset ('2-3/4 in or 2-3/8 in to match other doors on site').
-
Let it acclimate and keep it flat: 'Allow doors to acclimate for at least 24 hours to local conditions before installation or finishing', stored 'off of the floor' at 30-50% relative humidity.
-
Slab swap, hinges: 'Position the hinges on your door using the existing door as your template for hinge location. Mark the mortise areas with a utility knife, or butt hinge marking tool.
Rekey & Replace Door Locks Repair
-
Moving in means the seller, the agent and every contractor may still hold a key. (Kwikset support)
-
The classic failure: 'The key must be fully seated during programming'.
-
Kwikset's own pages give the turns two ways (quarter/half turn vs 90°/180°): follow the sheet that came with your lock.
-
Replacing a deadbolt instead: measure the backset first.
Sliding Glass Door Repair
-
Adjust rollers before any disassembly. PGT: the roller adjustment holes face the EXTERIOR (screws on the bottom outside of the panel, behind round hole plugs).
-
Panels go in the way PGT installs them: the top of the panel slips over the track header, then the bottom swings in over the sill and sets on the rollers; removal is that sequence reversed.
-
No universal roller exists: pull one old roller first and match housing and/or spring shape, wheel diameter, and wheel material (Prime-Line).
-
Don't lubricate the wheels: CGI/PGT says they "do not need lubrication since they contain a sealed ball bearing housing." Clean tracks and sills with a damp cloth or vacuum, and keep the weep (drainage) systems clear.
Storm Door Replacement
-
Measure before you buy, the way the Andersen/EMCO guide does: 'Measure the width at the top, middle, and bottom of the opening ...
-
Check the mounting surface, not just the hole.
-
Removing the old door: take the closer arms off their brackets first (a door with no closer swings free and can slam), pull the hinge pins or unscrew the hinge-side Z-bar from the casing, then the latch rail and the rain cap.
-
Rain cap first, then the hinge rail.
Window Blinds Install
-
Inside mount: measure width at top/middle/bottom and order the NARROWEST; measure height in 3 places and use the LONGEST; do NOT deduct for clearance (factory takes deductions, but only on inside mounts). (Bali 15-1412)
-
FL window openings are usually concrete-block returns behind stucco or 1/2" furred drywall — plastic drywall anchors there strip or crush.
-
Levolor: drill 1/16" pilot holes at the bracket marks, two screws per bracket, and use drywall anchors when mounting into drywall — "Failure to properly anchor screws could cause blind to fall.".
-
Center supports are load-bearing, not optional: Levolor ships 1 support bracket for 48-84" wide blinds, 2 for 84-96", 3 for 96-144" — space them evenly and hook the headrail into the support channel before locking the box brackets.
Window Painted Shut Repair
-
Failing paint on an old window is not evidence the wood beneath is bad, and that assumption is what gets sound, repairable windows replaced.
-
Cut the paint seal, do not pry it.
-
Painted shut and stuck are different problems with different fixes. A paint seal releases along the seam once cut.
-
If heat is involved, the glass comes out or gets shielded. NPS: "if any heat treatment is used, the glass should be removed or protected from the sudden temperature change which can cause breakage.".
Window Replacement
-
Orange County requires a permit — its Do I Need a Permit page answers "New exterior windows, exterior doors, garage doors? Yes, a building permit is required.".
-
Buying trap: the Florida Product Approval number must include the decimal — Orange County's form says "you must enter the entire number including the numbers after the decimal point.". (same search page)
-
Print the approval's Installation Instructions DRAWING and keep it on site — Orange County: "You are required to have the approved installation details on the jobsite for inspection.
-
A retrofit is NOT grandfathered.
Window Screen / Rescreen Repair
-
Spline is sized to the FRAME GROOVE, not the mesh, and it is not one number: Phifer's chart gives .140 (9/64") for standard fiberglass and pool/patio screen in both 5/16"x3/4" and 7/16"x3/4" frames, .125 (1/8") for aluminum and solar/PetScreen in those same frames, and .210 (7/32") for solar/PetScreen in 7/16"x1" frames.
-
Rescreen order (Phifer): strip the old spline, tape the frame's outside edges down but NEVER over the spline groove, lay the mesh square — overlap 1/2" on all sides for windows/doors, cut pool/patio panels 2-3" larger per side leaving 1-2" of excess — roll the fabric into the groove while holding it straight with your hand, press the spline in and seat EVERY corner with a screwdriver tip, then trim with the knife on the OUTSIDE edge of the spline groove so the blade can't cut the new screen.
-
FL lanai/pool cage mesh is not window cloth: 18x14 fiberglass is Phifer's pool-and-patio standard, and for midges near lakes/wetlands the answer is 20x20 No-See-Ums (or Solar Insect 20x30).
-
FL code trap (FBC 2023 Table 2002.4 notes): the screen-enclosure wind pressures assume 20x20x0.013" mesh; 18x14x0.013" may be multiplied by 0.88; and for densities GREATER than 20x20x0.013" you must use pressures for ENCLOSED buildings.
Roof, exterior & structure
16 repairs
Attic Insulation Repair
-
Florida is not on the national number: its Energy Conservation Code requires R-38 in the ceiling for Climate Zone 2, not the R-49 the IECC requires.
-
Depth alone does not prove you got what you paid for — bag count does.
-
STOP if the existing insulation is loose, pebble-like vermiculite. EPA's guidance is in capital letters: "YOU SHOULD ASSUME THE VERMICULITE CONTAINS ASBESTOS AND DO NOT DISTURB IT!".
-
Two clearances that start fires.
Attic Ladder / Access
-
Gas cylinders are under pressure: Louisville's current aluminum attic ladder manual says the unit 'is completely assembled. (yellow bolts = already corrected)
-
Load rating includes person PLUS everything carried (Werner: 'person plus materials being carried'; Louisville: 'Do not exceed the load capacity with the weight of the climber and materials being transported').
-
Leg-trim is the #1 install error: on Louisville's current aluminum models you don't freehand the cut — measure floor-to-ceiling and read the rail cut and adjustable-shoe cut from the manual's table (e.g., 8 ft to 8 ft 3 in = straight rail cut at line C, shoe cut at line D; 9 ft 11 in to 10 ft 3 in = no cut).
-
Never 'make it work' on height: if floor-to-ceiling exceeds the model's max ceiling-height range the ladder must not be used — return/exchange it (the Werner model covers 7'8" to 10'3"); aluminum models are trimmed only at the cut heights in the manual's table.
Concrete Walkway / Sidewalk Repair
-
PERMIT FIRST (Orange County 'Do I Need a Permit'): 'Driveway, walkway or concrete pad? Yes, anytime you are pouring concrete or placing pavers, a permit is required.
-
Thickness and base: Quikrete's sidewalk guide says sidewalks 'should be at least 4" (100mm) in thickness'; its slab guide excavates ~7" (3" compacted gravel + 4" concrete), tamps the gravel and dampens it with a hose right before the pour to limit shrinkage cracking.
-
Forms and fall: 2x4 forms on edge, 3" deck screws, stakes every 3 ft (Quikrete walkway guide).
-
Reinforcement goes in the MIDDLE, not on the dirt: Quikrete — support wire mesh on small stones so it is suspended at the midpoint of the slab (a fiber-reinforced mix eliminates the mesh).
Deck Board Replacement
-
"Above ground" is not decided by whether the wood touches dirt.
-
FBC-R R317.3.1: fasteners for preservative-treated wood must be "hot-dipped, zinc-coated galvanized steel, stainless steel, silicon bronze or copper" and "Staples shall be of stainless steel"; zinc coating weights per ASTM A153; connectors follow the connector maker, else minimum ASTM A653 G185.
-
Measure joist spacing BEFORE buying boards — the legal span changes with the material. FBC-R Table R507.7: 1-1/4 in. (5/4) wood decking = 16 in. o.c. max perpendicular / 12 in. diagonal; 2 in. wood = 24 in.
-
Sealing cuts is code, not a courtesy — FBC-R R317.1.1: "Field-cut ends, notches and drilled holes of preservative-treated wood shall be treated in the field in accordance with AWPA M4.".
Emergency Roof Tarp
-
Storm-specific hazards outrank the usual roof-walking rule: assume downed lines across the approach are live, and that decking under debris is punctured where it still looks solid.
-
Operation Blue Roof is the free federal option after major declared storms: USACE contractors install fiber-reinforced sheeting at no cost, but FEMA states only primary residences with standard shingled roofs are eligible and roofs with greater than 50 percent structural damage are not. (FEMA/USACE)
-
A blue roof is a 30-day covering by design, not a season's worth of protection — FEMA: "Blue Roofs are designed to last for 30 days.". (FEMA)
-
If you tarp it yourself, fasten it — don't weight it. (FEMA)
Exterior Stucco Patch Repair
-
Crack triage per SMA: hairline cracks under 1/16 in should NOT be patched (filler won't take; fog-coat or repaint instead); cracks wide enough to see from ~10 ft or that leak get filled with sanded acrylic stucco caulk (e.g.
-
Patch-size product map: shallow chips/holes up to 1/4 in deep = pre-mixed acrylic Stucco Patch (8650), applied in layers max 1/4 in each with 24 hr between layers; deeper holes (woodpecker damage) = cement Scratch & Brown Base Coat (1139) then a separate min 1/8 in Finish Coat (1201) per ASTM C926 — one thick lift of pre-mix will fail.
-
Old stucco/block needs a bond step or the patch delaminates: dampen cementitious substrates before applying cement stucco; use Concrete Bonding Adhesive 9902 (ASTM C1059) on old surfaces, and when applying Finish Coat over a previously dried base coat, replace 1/2 gal of mixing water with Acrylic Fortifier per 80 lb bag.
-
Curing is asymmetric: cement stucco patches need fog-spray moist cure ~twice daily for several days, but do NOT moist-cure acrylic or fortifier-modified products (they air-cure).
Gutters Repair
-
Hang to a sloped line, not a level: Amerimax says lower the string "approximately 1/4 in.
-
FLORIDA'S DISCHARGE RULE IS 1 FOOT, NOT 5 -- and gutters can be MANDATORY.
-
Drip edge: Amerimax's install guide says it helps "direct roof run-off into gutters" and its step is "If your house has drip edge, slip gutter under drip edge.".
-
Overflow is usually too few or too small downspouts, not slope. Amerimax: "Recommend one downspout per 20' of gutter," and by their own figures a 2x3 downspout drains 186 gallons per minute vs.
James Hardie / Fiber Cement Siding Repair
-
James Hardie's HZ10 line is engineered for the hurricane winds, coastal salt air, and humid Southern heat that fit Central FL - but JH's own instructions tell you to CONFIRM the correct HardieZone at HardieZone.com before ordering and warn that failing to follow the written instructions 'may affect warranty coverage.' The board carries State of Florida Product Approval FL#13192 outside the HVHZ (Miami-Dade/Broward HVHZ jobs instead follow Miami-Dade NOA 20-0730.06), and the approved install details must be on the jobsite, not improvised. (James Hardie HardiePlank FL#13192)
-
Blind-nailing is JH's preferred method and must NOT be mixed with face-nailing on the same wall (face-nail only where code requires it for high wind; a repair exemption is in JH Tech Bulletin 17). (James Hardie HardiePlank FL#13192)
-
Fasteners must be corrosion-resistant galvanized or stainless - JH recommends hot-dipped galvanized and recommends stainless steel 'when installing James Hardie products near the ocean, large bodies of water, or in very humid climates' (which fits humid Central FL and lakeside lots). (James Hardie HardiePlank FL#13192)
-
Water management is the whole game on a humid, termite-max FL wall: hold JH's minimum clearances - 6 in. siding-to-finished-grade, 1 in. above roofs/decks/paths/steps and gutters, 1/2 in. off masonry/mortar, and 1/4 in. (James Hardie HardiePlank FL#13192)
Pressure Washing
-
Tip color is spec, not preference (SIMPSON manual): red 0-deg = unpainted metal/concrete only, "DO NOT use on wood"; yellow 15-deg and green 25-deg are both HIGH-pressure tips that SIMPSON lists for unpainted surfaces, stucco included; white 40-deg = painted stucco, vinyl, painted siding, and the only tip near windows (stay 4 ft+ away).
-
Vinyl siding: 1,500 PSI min to 2,400 PSI max with a 40-deg tip, wand horizontal at eye level (Georgia-Pacific). (Sto)
-
Mildew on vinyl siding (GP's mix): 1 qt 5% sodium hypochlorite + 2/3 cup TSP + 1/3 cup detergent in 3 qt water; do not exceed the stated concentrations, test an inconspicuous spot first, scrub bottom-to-top, rinse thoroughly with clear water.
-
Never aim upward: water driven up behind siding laps collects there and causes leaks, streaking, or decay (GP). Wash siding bottom-up, then rinse top-down (SIMPSON).
Roof Leak & Re-Roof Repair
-
The expensive mistake in Florida is assuming small patches keep you out of a full re-roof.
-
Getting up to look is the riskiest part of the whole job.
-
The age of the existing roof decides the answer, so establish it first.
-
Re-roofing an older Orange County house triggers mitigation retrofits, and the county publishes the exact specs.
Roof Tile Repair
-
Check the layer under the tile before the tile.
-
Tile breaks under foot, so getting up there is both the danger and the main cause of MORE broken tile.
-
Florida's standard is the FRSA-TRI Florida High Wind Concrete and Clay Tile Installation Manual, 7th Edition (effective code date 12/31/23), whose repair procedure reads verbatim: "Break out and replace damaged roof tile.
-
Match the attachment system already on the roof — mechanically fastened, adhesive-set and mortar-set are different systems, and FRSA/TRI's compatibility tables exist to reduce the inadvertent "mixing of systems, which can lead to a reduction in the life span of a tile roof system.".
Shed & Accessory Structure
-
Orange County's answer is blunt: "Yes, all structures require a permit.".
-
Submittal trap on the $12 route: the dimensioned site plan or survey must show the structure's location AND its "proposed height of the structure as measured to the peak of the roof" — not wall height.
-
FBC-R R301.2.1.2: "Storage sheds that are not designed for human habitation and that have a floor area of 720 square feet (67 m2) or less are not required to comply with the mandatory wind-borne debris impact standard of this code.".
-
Check the kit's rated wind speed BEFORE buying.
Soffit & Fascia Replacement
-
Soffit and fascia are two different parts. The fascia is the vertical board at the roof edge, under the drip edge; the soffit is the horizontal underside of the overhang between the fascia and the wall.
-
The soffit is half of your attic's ventilation, and the code specifies how much.
-
Get the vent rating AND its unit in writing — the code counts net free area, not panel width.
-
Screening is a code detail.
Stair Handrail / Deck Guardrail Repair
-
Interior stair handrail (FBC-R R311.7.8): a graspable rail is required on at least one side of any flight of 4+ risers, its top 34-38 in high, continuous for the full length of the flight, and held 1-1/2 in off the wall, with a Type I or II grip size (R311.7.8.3). (Orange County Building Safety)
-
A guard is fall protection, and the trigger is two measurements, not one: it is required on open-sided walking surfaces -- stair, ramp, landing, deck or balcony -- 'located more than 30 inches measured vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the open side.' It must be at least 36 in high, let no opening pass a 4-in-diameter sphere, and 'Insect screening shall not be considered as a guard' (FBC-R R312). (Orange County Building Safety)
-
Stair openings use looser spheres than level guards: on the OPEN SIDE of stairs the guard/handrail top runs 34-38 in above the nosing line, its openings must block a 4-3/8 in sphere, and the triangle formed by riser, tread and bottom rail must block a 6-in sphere. (Orange County Building Safety)
-
A wobbling guard is failing a design load, and the sphere test alone is not compliance: Orange County's plan checklist makes you document both 'Guards and handrails: 200psf' and, separately, 'Guard in-fill components: 50psf' (FBC-R Table R301.5).
Termite Damage & Wood Rot Repair
-
Florida law puts wood rot in the same box as termites.
-
"Dry rot" is a misnomer, and the numbers are why.
-
Probe, do not look.
-
Read what the report says it is NOT — all three disclaimers are printed on Form 13645 itself.
Wood Fence Repair
-
BEFORE any post hole: Florida law (Ch.
-
Post hole spec (Quikrete): diameter = 'three times the width of the post'; depth = '1/3 to 1/2 of the above-ground length of the post, plus 6"' for a compacted gravel base — the gravel is the drainage layer under the concrete, don't skip it.
-
Two rot defenses FL DIYers skip.
-
A post rotted at the grade line has lost its structural section where bending load peaks — full-depth replacement to the embedment spec is the durable fix, and a stub sistered above grade can't restore the 1/3-1/2 embedment.
Walls, floors & interior finishes
16 repairs
Bathroom Mold Repair
-
Mold is a moisture problem, not a stain problem — EPA: "There are many types of mold, and none of them will grow without water or moisture," and "If you clean up the mold, but don't fix the water problem, then, most likely, the mold problem will come back.".
-
Do not reach for bleach first — EPA's position is the opposite of the folk wisdom: "The use of a chemical or biocide that kills organisms such as mold (chlorine bleach, for example) is not recommended as a routine practice during mold cleanup.".
-
Ten square feet is the hinge, and in Florida it moves two things at once.
-
Know what gets cleaned, what gets thrown out, and what not to run.
Cabinet Hinges & Handles Repair
-
No permit for swapping hinges or pulls. FBC 105.2 lists cabinets among exempt finish work as long as you are not moving plumbing or electrical; exempt still means code-compliant.
-
Before you buy, match the hinge TYPE (overlay, half/dual overlay or inset) and the existing cup holes.
-
Three adjustments.
-
Use a Phillips screwdriver, not a power drill: Blum recommends it for control and to prevent damage to the adjustment screw.
Drywall Anchors & Hanging Heavy Things Repair
-
The number on the package is not the number you can hang.
-
Leverage kills anchors: Toggler says 'moving objects away from the wall greatly reduces what an anchor can safely carry'.
-
When there is no stud: a strap-style toggle. (see the drywall repair guide)
-
Lighter anchors, lighter jobs (Simpson Strong-Tie Sure Wall line, ultimate loads): hollow-wall anchor up to 75 lb — 'it cannot simply be hammered into the drywall'; spring toggle up to 90 lb; self-drilling toggle up to 65 lb with household tools; plastic plug up to 65 lb.
Drywall Repair
-
Compound choice: deep fills / same-day multi-coat = setting-type 'hot mud' (USG Sheetrock® Brand Easy Sand™ Setting Type Joint Compound — the number IS the working time: 20/45/90 min); USG calls it 'chemically setting' with low shrinkage, 'ideal for heavy fills', and the suffix is an approximate working time.
-
Always spot-prime the patch before painting — DAP: flatten the patch with medium-grit then finish with fine-grit sandpaper, and prime repaired areas before painting for even paint coverage.
-
FL garage fire wall (2023 FBC-R 8th Ed., Table R302.6): min 1/2 in. gypsum on the garage side, 5/8 in.
-
Wet areas (2023 FBC-R): water-resistant gypsum board can't go over a Class I/II vapor retarder in a shower/tub compartment (R702.3.7) and can't be used where directly exposed to water or continuous high humidity (R702.3.7.1).
Drywall Texture: Knockdown & Orange Peel Repair
-
Name the pattern before you buy anything. Orange peel is a fine spray left as it lands; knockdown is a heavier splatter flattened with a knife once it starts to set.
-
A patch blends only if it starts primed and flat.
-
Small patch: an aerosol can.
-
Bigger areas or a whole room: a hopper gun and compressor (USG: 'Small jobs can be completed using a Hopper Gun... with separate compressor').
Grab Bars, Towel Bars & TP Holders Repair
-
A grab bar is only as good as what it is screwed to. (Delta)
-
Fitting a bar to 16-inch studs: a 16 in or 32 in bar lands on two studs horizontally; 'Diagonal/angled installation is possible only with grab bars 24 in or longer' (Moen), and Delta allows 'Diagonal, horizontal, and vertical'. (ADA 604.5)
-
No stud where you need one: use the bar maker's hollow-wall anchor, not a plastic plug. (Moen, Delta)
-
Drilling tile: tape the spot, 'try to locate screw hole(s) on grout line' where you can (Arista), then 'Drill pilot holes through the tiles by using a 1/4-inch carbide tip drill bit. (Moen)
Hardwood Floor Refinishing
-
Engineered wood: measure the wear layer BEFORE planning a sand — at a floor-register cut, under a transition molding, or in a board gap down to the top of the tongue. (NWFA)
-
Recoat prep decides adhesion, and the can tells you whether a recoat is even allowed. (Minwax)
-
Cure is not dry. Minwax Ultimate Floor Finish: recoat after 'at least two hours, but less than 24 hours' — inside that window no sanding is needed, but past 24 hours 'sand the finish lightly with 220 grit sandpaper. (Minwax)
-
Run the A/C while finishing. Minwax bases its dry times on 'good ventilation, temperature of 77 oF and 50% relative humidity. (Minwax / NWFA)
Interior Painting
-
Prep before a brush touches the wall: Sherwin-Williams says wash with a mix of lukewarm water and mild soap, gently rubbing in a circular motion, then rinse with a slightly damp cellulose sponge and let it dry. (Sherwin-Williams; EPA)
-
Match filler to the defect: lightweight spackle (e.g., DAP Fast 'N Final) for nail holes and small dents — DAP: lightweight spackling is 'Best for small nail holes and shallow dents' and 'typically doesn’t require sanding'; heavyweight is 'ideal for medium-size holes' and 'should be sanded smooth'. (DAP; Sherwin-Williams)
-
Spot-prime every bare patch before the color coat. (Sherwin-Williams; DAP)
-
Cut in one wall at a time: Sherwin-Williams says 'A 1-2" brush offers good control so it is well-suited for detail work such as cutting in around windows or painting molding'; lay a band along the ceiling, corners and baseboard, then immediately roll the field while that band is still wet so it blends. (Sherwin-Williams)
Kitchen Cabinet Painting
-
Clean before you sand, or you grind the grease in. (Rust-Oleum)
-
Take it apart and label it. Rust-Oleum: 'take cabinet doors off hinges and drawers out of frames.
-
Primer by surface.
-
Pick a cabinet enamel and obey its clock.
Kitchen Tile Backsplash Repair
-
Painted drywall is a fine backsplash substrate as long as it is dry-area wall and clean: Custom's AcrylPro lists 'Gypsum wallboard (interior dry areas)', MAPEI's Type 1 'interior walls in dry areas only. (TEC)
-
Layout decides how it looks. (Daltile)
-
Mastic or thin-set: mastic (ANSI A136.1 Type 1) is the easy one for a dry backsplash with small ceramic tile, and every maker caps it.
-
Glass tile is a thin-set job in white. (TEC, Daltile)
Laminate Countertop Repair & Replacement
-
Chips and open seams: Kampel SeamFil is the repair paste the laminate makers point to, and it has rules.
-
A lifted edge or bubble is a contact-cement job (DAP Weldwood TDS): both surfaces 'clean, dry and free of foreign materials', air and surfaces 'above 65°F for a minimum of 24 hours before and after application'.
-
Heat is what kills laminate.
-
Cleaning that does not etch it: 'a clean, damp, nonabrasive cotton cloth and a mild liquid detergent'; 'Do not flood the laminate, especially near seams, since water can penetrate and cause the substrate to swell'; 'Never use cleaners containing acid, or alkali' (Formica names ceramic-cooktop, drain, toilet-bowl, tub-and-tile and oven cleaners).
Luxury Vinyl Plank Flooring Repair
-
Florida slab-on-grade: test it, never eyeball it. (LifeProof Rigid Core install guide)
-
Keep the AC running the entire job: LifeProof states 'The HVAC system must be on and functional before, during, and after installation' and flatly bars installs in 'non-temperature controlled rooms or homes.' Hold the room at 50-100°F and 35-85% RH.
-
Flatten and prep the slab before a single plank: min 3,000 psi concrete, flat to 1/4 in. in a 10 ft. span with no slope over 1 in. (LifeProof Rigid Core install guide)
-
Leave a 1/4 in. expansion gap around the ENTIRE perimeter and against every vertical obstruction — walls, door casings, pipes, island bases — and grow it to 1/2 in. (LifeProof Rigid Core install guide)
Popcorn Ceiling Removal Repair
-
Start with a lab test, not a scraper: spray-applied ceiling texture was not federally banned until 1978.
-
Do not sand, scrape, dry-remove — or sample — before you know.
-
Florida's homeowner exemption is narrower than people assume.
-
"Under 160 square feet is exempt" is two different rules sharing one number, and neither is a homeowner pass.
Squeaky Floors Repair
-
A squeak is a fastener rubbing, not a structural failure — and in Orlando you almost always fix it from ABOVE, because there is no crawlspace to work from.
-
Do not shim the gap with a shingle or a tapered wedge.
-
Punching a popped nail back down buys weeks, not years. APA: "Note that setting a popped nail may only provide temporary relief.".
-
The scored repair screw works on a manufacturing detail worth understanding.
Tile & Grout Repair
-
Joint-width rule is hard: unsanded grout ONLY for joints under 1/8 in; sanded for 1/8-1/2 in; never blend the two (TCNA).
-
Cement grout will NOT bond to old grout - a skim coat over cracked grout fails. Remove at least 2/3 of joint depth (Mapei) / 1/2-3/4 of tile thickness (Custom) before regrouting.
-
Shower-use wait is longer than generic '24 hours': premixed grout (SimpleGrout, CUSTOM TDS-181) needs 3 days before water on shower walls and 7 days on shower floors.
-
Never grout corners, tub-to-tile joints, or any change of plane - use 100% silicone (or urethane) per TCNA EJ171; acrylic/siliconized latex caulk dries hard and re-cracks.
Wall & Ceiling Texture Removal Repair
-
Test before anything gets sanded or scraped.
-
Pre-1978 home: assume lead in the paint over the texture until tested.
-
Painted or not decides the method.
-
Skim coat with the right mud.
Yard, pool & garage
6 repairs
Garage Door Hurricane Bracing
-
The rating is a PAIR and the suction half is the one that fails. (DASMA TDS 152)
-
"Hurricane-rated" is TWO different ratings and buyers routinely purchase the wrong one.
-
Do not accept a countywide number.
-
Both folk fixes fail, and TDS 152 sharpened the first one in Rev.
Garage Door Opener Repair
-
HARD STOP on springs, cables, and bottom brackets — Clopay: "If your springs are broken or improperly tensioned, do not adjust or remove them yourself," "The bottom brackets on all garage doors must not be removed while the door is under tension," and frayed cables "are in danger of breaking and could cause serious injury or property damage.".
-
Photo-eye sensors mount "no higher than 6 inches (15 cm) above the floor.".
-
Safety reversal test — monthly and after ANY adjustment ("After ANY adjustments are made, the safety reversal system MUST be tested"): with the door fully open, lay a 2x4 flat (a 1-1/2 in.
-
Program TRAVEL first — on a Security+ 2.0 / myQ opener you do NOT set force by hand: "The force is adjusted automatically after you program the travel.".
Garage Door Panel Replacement
-
Replacement sections are dealer-ordered by exact model, not off-the-shelf: Clopay identifies a door built in the last 10 years by the 15 to 16 digit serial number on the interior of the bottom section, and a matching section exists only 'provided we still manufacture the door model you own'. (Clopay FAQ)
-
Triage the dent before ordering a section: Clopay says that if the door uses metal, check whether it is 'rusted or heavily dented'; 'If dents are minor and your door is uninsulated, you may be able to push out the dings from the inside of the door. (Clopay Service & Replacement)
-
HARD STOP before pulling any section: the torsion spring and lift cables stay loaded even with the door closed. (Clopay Service & Replacement)
-
In Florida the door is a wind element, not trim: DASMA quotes a Florida source calling the garage door the area of the home 'most likely to fail first' in a storm, and another that 'The bigger the door, the higher the pressure, making a double-car garage more vulnerable.' DASMA's advice for a door not built for high winds includes making sure 'the track is strong and anchored to 2x4s inside the wall' and meeting 'at least' the Florida building code's standards for the wind zone. (DASMA)
Irrigation Valve / Sprinkler Head Repair
-
Rain Bird head swap: "Clean the threads and apply plumber's tape to the male connector.
-
Never mix rotors and spray heads on one valve — Rain Bird: "You want to avoid mixing components with different precipitation rates on the same valve whenever possible," so one area floods while the other stays dry and no controller setting fixes it.
-
Heads that dribble AFTER the zone shuts off are usually not a bad valve.
-
Zone won't come on — work this order (Hunter), don't start by buying a valve.
Pool Pump Basics
-
Prime-loss is usually not pump death.
-
NEVER run the pump dry: water is the coolant and lubricant for the mechanical shaft seal.
-
SAFETY: if the pump failed to prime or ran without water, do NOT open the strainer pot — Pentair: such pumps "may experience a build up of vapor pressure and may contain scalding hot water.
-
MOTOR/PUMP SWAP — the bonding conductor is not optional and is NOT the ground wire (the motor has a separate GROUND SCREW and BONDING LUG).
TV Mounting On Block Walls
-
Follow the MOUNT's own concrete instructions, not generic anchor advice — and check the wall qualifies first. Sanus XF228 and Chief XSM1U/XTM1U both list the concrete option ONLY for a bare solid concrete wall 8 in.
-
Tighten the lags only until the washers pull firmly against the wall plate — Sanus: 'Improper use could reduce the holding power of the lag bolts.
-
The Orlando trap: your block wall is not 'bare'. Interior drywall sits on wood furring — FBC-R R702.3.2 permits furring 'not less than 1-inch by 2-inch (25 mm by 51 mm) nominal dimension...
-
If you do use concrete screws instead of the kit's sleeve anchors, the bit pairing is NOT intuitive — Tapcon: '3/16" Tapcon requires 5/32" bit, 1/4" Tapcon requires 3/16" bit.' Drill with a hammer drill, 'Hammering function ON,' to a hole '1/4" deeper than anchor embedment'; then 'Clean using a blow out bulb or compressed air, remove dust from hole'; then drive the anchor 'until fully seated' with 'Hammering function OFF.' Tapcon's bit guide sets embedment at 1 in.
Hiring & permits
1 repair
Hiring A Contractor Repair
-
Every question worth asking a contractor has a checkable answer, and the license comes first — search the name or number yourself at the DBPR license lookup (myfloridalicense.com); never accept a photo of a card.
-
Ask what deposit they want, because Florida attaches a clock to the answer.
-
Ask WHO pulls the permit, and do not trade one away for speed.
-
Florida's under-$7,500 permit waiver (HB 803, signed 2026-05-06, effective 2026-07-01, now FS 553.79(1)(g)) is real but narrower than contractors quote it.
General guidance, not professional advice. Know when to stop and call a pro.